10 Questions You Should to Know about permanent magnet dc generators

Author: yong

May. 26, 2025

82

0

0

Answering Seven Common Questions on Generator and Motor ...

For any given brush installation, there is an optimum amount of brush pressure. If the pressure is decreased below this amount, the total wear increases because the electrical wear increases. If the pressure is increased above the optimum amount, the total wear again increases because mechanical friction increases.

Link to dingbo

Always make sure that the brush pressure is set to the manufacturer's recommended level. If wear is still excessive, you should investigate the type and size of brush being used. Remember, current density (amperes per sq in. of brush) must be correct for the application. Proper current density is required to make certain that a lubricating, conductive film forms on the commutator or slip ring. This film is composed of moisture, copper, and carbon. Insufficient current density inhibits the formation of this film and can result in excessive brush wear.

Also, very low humidity environments do not provide enough moisture for the formation of the lubricating film. If excessive brush wear is a problem in such an environment, you may have to humidify the area where the machine is operating.

Check out this additional asset from our team:
EC&M eBook: The Secret to Better Motor Health

Question No. 3: What is service factor?

Service factor is the load that may be applied to a motor without exceeding allowed ratings. For example, if a 10-hp motor has a 1.25 service factor, it will successfully deliver 12.5 hp (10 x 1.25) without exceeding specified temperature rise. Note that when being driven above its rated load in this manner, the motor must be supplied with rated voltage and frequency.

Keep in mind, however, that a 10-hp motor with a 1.25 service factor is not a 12.5-hp motor. If the 10-hp motor is operated continuously at 12.5 hp, its insulation life could be decreased by as much as two-thirds of normal. If you need a 12.5-hp motor, buy one; service factor should only be used for short-term overload conditions.

Question No. 4: What is a rotating magnetic field, and why does it rotate?

A rotating magnetic field is one whose north and south poles move inside the stator, just as though a bar magnet, or magnets, were being spun inside the machine.

Look at the 3-phase motor stator shown in the accompanying diagram. This is a 2-pole stator with the three phases spaced at 120 [degrees] intervals. The current from each phase enters a coil on one side of the stator and exits through a coil on the opposite side. Thus, if one of the coils is creating a magnetic north pole, the other coil (for the same phase) will create a magnetic south pole on the opposite side of the stator.

At Position 1, B-phase is creating a strong north pole at the upper left and a strong south pole at the lower right. A-phase is creating a weaker north pole at the lower left and a weaker south pole at the bottom. C-phase is creating an overall magnetic field, with its north pole in the upper left and its south pole in the lower right.

At Position 2, A-phase is creating the strong north pole at the lower left and a strong south pole at the upper right; thus the strong poles have rotated 60 [degrees] counterclockwise. (Note that this 60 [degrees] magnetic rotation exactly corresponds to a 60 [degrees] electrical change in the phase currents.) The weak poles also have rotated 60 [degrees] counterclockwise. This, in effect, means that the total magnetic field has rotated 60 [degrees] from Position 1.

With a more detailed analysis, we can show that the magnetic field strength rotates smoothly from Position 1 to Position 2 as the currents in each of the phases varies over 60 electrical degrees. Analysis of Positions 3, 4, 5, and 6 shows that the magnetic field continues to rotate.

The speed at which the magnetic field rotates is called the synchronous speed and is described by the following equation:

S = (f x P) / 120 where S = rotational speed in revolutions per minute f = frequency of voltage supplied (Hz) P = number of magnetic poles in the rotating magnetic field

If a permanent magnet were placed into this stator, with a shaft that allowed it to rotate, it would be pushed (or pulled) along at synchronous speed. This is exactly how a synchronous motor operates, except that the rotor (field) magnetic field is created by electromagnetism instead of a permanent magnet.

Want more information on permanent magnet dc generators? Feel free to contact us.

Featured content:
NEMA vs. IEC Motor Standards: What is the Difference?
Squirrel Rotors: The Comprehensive Guide - Grand - Slip Rings
What is wound rotor motor and Why Do We Use Them?
Why Choose Wound Rotor for Induction Motors?
How Will LV Electric Motors Transform Industries?
What to Look for in Medium Voltage Squirrel Cage Motors Supplier in China?
What Should I Consider When Buying Slip Rings?

An induction motor rotor is composed of short-circuited windings, and a current is induced in the rotor windings when the rotating magnetic field cuts through them. This current creates a field that opposes the rotating field. As a result, the rotor is pushed (or pulled) around by the rotating field. Note that the induction motor rotor can't rotate at synchronous speed, since the rotating field must cut through the rotor windings to create the torque. The difference between synchronous speed and the actual rotor speed is called the percent slip; it is expressed as a percentage.

Single-phase motors also have a rotating magnetic field. The rotating field required to start the motor is generated from a second winding called a starting winding. After the motor is up to speed, the starting winding is disconnected, and the rotating field is developed by interaction of the stator main winding and the rotor.

Question No. 5: How does an induction generator work?

An induction generator is identical in construction to an induction motor. The stator windings are connected to a 3-phase power system, and the three phases create a rotating magnetic field. The induction generator's rotor is rotated by a prime mover, which turns faster than synchronous speed. As the rotor windings cut through the rotating field, a current is induced in them. This induced current creates a field that, in turn, cuts through the stator windings to create power output to the load.

The induction generator thus draws its excitation from the power system to which it's connected. The induction motor must have synchronous generators connected to its stator to start generating. After the induction generator is operating, capacitors can be used to supply the excitation.

Question No. 6: Why are generator and motor bearings insulated?

The magnetic field inside a motor or generator is not completely uniform. Thus as the rotor turns, a voltage is developed on the shaft longitudinally (directly along the shaft). This voltage would cause microcurrents to flow through the lubricant film on the bearings. These currents, in turn, would cause minor arcing, heating, and eventual bearing failure. The larger the machine is, the worse the problem becomes.

To avoid this problem, the rotor side of the bearing body is often insulated from the stator side. In most instances, at least one bearing will be insulated, usually the one farthest from the prime mover for generators and farthest from the load for motors. Sometimes, both bearings are insulated.

Question No. 7: How do AC generators control vars, voltage, and power?

Although the controls of a generator do interact, the following generalities are true.

  • The power output of a generator is controlled by its prime mover.
  • Voltage and/or var contribution of a generator is controlled by the exciter current level.

For example, let's assume that an additional load is connected to the output of a generator. The added current flow will increase the strength of the armature's magnetic field and cause the generator to slow down. In order to maintain frequency, the generator's governor will increase the power input to the prime mover. Thus, the additional power required of the generator is controlled by the prime mover input.

In our example here, the net magnetic flux in the air gap will decrease, since the armature increase opposes the field flux. If the field flux is not increased to make up for this change, the generator output voltage will decrease. Thus, the excitation current is used to control the output voltage.

Let's look at another example for further clarification. Suppose an additional VAR load is added to our generator. In this circumstance, the generator output current will increase again. However, since the new load is not "real" power, the prime mover needs to be increased only enough to overcome the additional IR drop created by the extra current.

As a final example, let's assume that we have two or more generators running in parallel and feeding a load. Generator 1 (G1) is carrying all the load (real and reactive) while Generator 2 (G2) is running at zero watts and zero VARS. If the operator for G2 opens the prime mover throttle, G2 starts to feed watts to the system. Since the connected load hasn't changed, both generators will speed up unless G1 throttles back.

As G2 picks up an additional share of the load, it requires an increased field flux. If the G2 operator does not increase the G2 field, G2 will draw its additional excitation from G1, requiring G1 to increase its excitation level. If neither G1 nor G2 increase the excitation level, the overall system voltage will go down.

John Cadick, P.E. is president, Cadick Professional Services, Garland, Tex., an interNational Electrical Testing Assoc. (NETA) member.

If you want to learn more, please visit our website volvo generator.

DC permanent Magnet Motor Theory Questions - Eng-Tips

Hi guys,

I need some help with my understanding of permanent magnet DC motor operation. I am building a spreadsheet to model motor performance. I'm an ME and my electrical knowledge is poor so I have started with the theoretical side to help develop my understanding. I have a few good books on the way, but would like to start getting feedback here as well so any help you can provide would be greatly appreciated.

The motor I am attempting to model is the AGNI 95R which can be reviewed here:


My spreadsheet is attached.

My first question is with current draw. Based on the information I have been supplied, both measured and derived from manufacturer performance figures, this motor has an armature resistance of 0. ohms. This seems very low to me. Therefore, at 60v terminal voltage and low shaft speeds, hence low counter emf voltages, I see very high current draws. Theoretically speaking, is this correct or am I overlooking something?

If I was correct above, my second question is what occurs when you can't supply the required current? Assume I will only be able to provide this motor with 240 amps continuous. During an unloaded acceleration run, will it draw the full 240 amps from 0 rpm to the rpm point where the terminal voltage and counter emf voltage combine to require less current than 240 amps?

I'm sure I will have more questions, so thanks in advance for your time and help.

Chris Skarzenski I always think of the difference between a DC motor and a DC generator as just a few volts or a few RPM. That is for the types of motors that are suitable for use as generators, but I find that the exercise helps to get a feel for other motor applications.
Suppose a generator is running at RPM and generating 100 Volts. It is now connected to a 100 Volt source. Nothing happens, there is no current flow. Now increase the voltage a few volts. Current will flow in a direction to increase the speed of the machine. Decrease the voltage a few volts. Now the machine will force current through the source.
Likewise, increase the RPM a few Rs and the machine will generate and force current through the source. Drop the RPM a little and the machine will draw current from the source and try to maintain speed.
The next question, How much.
Assume the source is a battery or another generator (large enough to be stable with the changes in load).
At normal speeds things are pretty linear. RPM / 100 Volts gives 10 RPM/Volt.
If we change the RPM by 10 R, the voltage will change by one volt.
The back EMF 1 volt different from the applied voltage and the effective voltage driving current through the armature will be 1 Volt.
this motor has an armature resistance of 0. ohms
One volt will cause about 80 amps to flow and the motor. How do we change the RPM? We change the load. If we apply enough load to drop 10 RPM the current will increase by about 80 amps. 80 Amps x 100 Volts (Applied voltage) is Watts. A load of one horsepower will cause the voltage to drop a little less than 0.1 Volt.
This is in a different format than you have presented, but it may give you a feel for motor characteristics.
I hope that you can follow my explanation.

Bill
--------------------
"Why not the best?"
Jimmy Carter waross

Thanks for the excellent information but I have another question for you. We have a 750 VDC, HP, rpm motor that is used to test a gear box under a load. However, our customer was curious about running our test at say 25% speed for a sustained period of time without the test gear box being under any load.

I am extremely new to this field and my gut tells me that simply supplying 25% of the voltage to the motor would cause the motor rotation to be 25% of the max speed but I feel like that is too simple and I may be overlooking something.

Any input is appreciated and thanks in advance.

KEV Let's consider a motor on a load that will overhaul and tend to overspeed the motor.
There will be a speed at which the back EMF will equal the applied voltage and the current will be zero. Slower and the back EMF will drop and the m,otor will start to draw current and develop positive torque. Faster and the back EMF will increase above the applied voltage and the motor will become a generator and try to export energy.
This relationship is quite linear. You may use this as a rule of thumb but be aware that there may be a few percent error.
Comparing a fully loaded motor at 100% voltage to a lightly loaded motor at 25% voltage will introduce a few percent error. For the majority of applications this error may be ignored. In some of the remaining applications the automatic control systems will correct the error.
If you look at the percent difference between no load speed and full load speed, the errors may be expected to be contained within that envelope.

Bill
--------------------
"Why not the best?"
Jimmy Carter
Featured content:
Unlocking Efficiency: How Wound Rotor Motors Can Solve Your Biggest Industry Challenges
7 Amazing Benefits of Using a Low Magnetic Motor for Efficiency
7 Key Facts About Synchronous Speed Definition You Need to Know
High Efficiency Explosion-Proof Motor vs Standard Motor: Key Differences Explained
Key Considerations for Buying Squirrel Cage Induction Motors
How Can Remote Monitoring Ensure Custom Motors' Safety and Performance?
Essential Guide to Choosing Slip Ring Water Cooling Motors: Solutions to Common Issues

Comments

Please Join Us to post.

0

0/2000